Section 206.5.1 covers scoping requirements in the most current ADA Standards for the use of platform lifts due to existing site constraints.
Search Results "Clear Floor Space"
Commonly Searched Documents
-
Existing Site Constraints: ADA Standard Section 206.7.5
-
Fixed Seating and Tables
An accessible route provides access to each accessible table and a clear floor area 30 inches by 48 inches is provided at each accessible seating location....
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
-
4.23.9* Medicine Cabinets
If medicine cabinets are provided, at least one shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor space. The floor space shall comply with 4.2.4....
-
4.23.9* MEDICINE CABINETS
If medicine cabinets are provided, at least one shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor space. The floor space shall comply with 4.2.4....
-
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impacts Performance Phase 2: Final Report
Independent Wheelchair Transfers in the Built Environment: How Transfer Setup Impact Performance Phase 2: Final Report REPORT PREPARED FOR: U.S ACCESS BOARD, WASHINGTON,...
-
Mounting Height and Location
As a result, the height of braille and raised characters are held to the same range: 48 to 60 inches above the floor or ground (703.4.1)....
-
Check-Out Aisles [7.3]
Clear passage must be at least 36 inches wide continuously and 32 inches at a point (24 inch maximum distance). Access can be provided at aisles shared between two check-outs....
-
1134A.6 Showers
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
11B-206.7.5 Existing site constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...
-
R308.2 Transit Shelters
Transit shelters shall provide a minimum clear space complying with R404 entirely within the shelter....
-
14. Parking Spaces and Garages
[See subsections ...]
-
Knee and Toe Space Depth
[See subsections ...]
-
Common Questions (Parking Spaces)
Common Questions
-
Sales and Service Elements and Spaces
[See subsections ...]
-
Question 16
., listening stations for recordings, try-out areas for electronics) clear of obstacles that block floor or knee clearance?...
-
Value Contrast (slide 9)
Furniture and open spaces There are so many cases of dark furniture on dark carpeting or on patterned floors, and also white leather furniture on white or very light floors....
-
R406.3 Unobstructed Side Reach
Where a clear space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380...
-
CARRIAGE UNIT
[HCD 1-AC] A dwelling unit with living space on one or more floors immediately above a Group U, private garage or garages....
-
Section 2. Multistory dwelling unit
"Multistory dwelling unit" means a dwelling unit with finished living space located on one floor and the floor or floors immediately above or below it....
-
709.4 Continuity
Smoke barriers shall form an effective membrane continuous from outside wall to outside wall and from floor slab to floor or roof deck above, including continuity through concealed spaces...
-
Common Problems with Parking
Common Problems with Parking Ø There are too few "accessible" spaces. Ø There are no "van accessible" spaces....
-
Ground Surfaces
Section 1008.2.6 of the 2010 Standards provides technical requirements for accessible ground surfaces for play areas on accessible routes, clear floor or ground spaces, and turning spaces...