If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
Search Results "Clear Floor Area"
Commonly Searched Documents
-
D6
-
Forward Approach
Clear floor space must be provided to the face of the unit since the seated forward reach does not extend much beyond the toes....
-
4.7.3 Slope
The slope of the clear floor or ground spaces required by section 4.0 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
Side Reach [§308.3]
The maximum reach depth for this range is 10” measured from the available clear floor space....
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
711.4.1 Through penetrations
Penetrating items with a maximum 6 inch (152 mm) nominal diameter shall not be limited to the penetration of a single fire-resistance-rated floor assembly provided that the area of the penetration...
-
R308.1 Transit Stops
Where security bollards are installed at transit stops, they must not obstruct the clear space at boarding and alighting areas or reduce the required clear width at pedestrian access routes...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor. 2. Floor space....
-
11B-221.2.4 Temporary structures
Exception: When an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an...
-
Drinking Fountain Scoping for Exterior Sites
For example, if drinking fountains are provided outside a building and on each of its floors, then dual access must be provided at exterior locations and on each floor....
-
When alterations are made on an upper story of a facility, is vertical access required?
If alterations are made to a primary function area on an upper floor, an accessible path of travel to the area is required to the extent that the cost is not disproportionate (i.e., more...
-
E2-2. Overhead Objects
Are pedestrian routes leading to or serving the voting area free of overhead objects with the bottom edge lower than 80 inches above the floor?...
-
Guidance Concerning Service Animals
[See subsections ...]
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
When do path of travel and/or accessible routes apply? …new construction? …alterations to a parking area? …alterations to a building associated with parking, such as expansion or remodel?
In general, when alterations are made to existing buildings or facilities, an accessible path of travel to the specific area of alteration shall be provided; this path of travel includes...
-
At least one percent of all fixed seats in all seating areas must be aisle seats with no armrest, or with a removable or folding armrest
• In addition to wheelchair seating locations, at least one percent of all fixed seats in all seating areas must be aisle seats with no armrest, or with a removable or folding armrest, on...
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...