These include an exception from the requirement for an accessible route in private multi-level buildings and facilities that are less than three stories or that have less than 3,000 square...
Search Results "Floor-Level Exit Sign"
-
F214 Washing Machines and Clothes Dryers
-
Play Tables
Play tables may be located at a ground or elevated level in a composite play structure....
-
Temporary Solutions for Election Day
Or, if a church’s basement is used as a polling place and it is not accessible, perhaps one of the ground floor rooms could be used as the accessible voting area....
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
- Panda S.85 All Aluminum Slim Profile Lift and Slide System
-
1008.1.9.7, Item 5
A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING....
-
11B-703.6 Pictograms
Pictograms and other symbols, such as the International Symbol of Accessibility (ISA), which are included on signs with raised characters and Braille are not required to be raised....
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
Counter Slope: ADA Standard Section 406.2
Section 406.2 covers the current ADA Standards for counter slope of adjoining gutters and road surfaces immediately adjacent to curb ramps.
- TownSteel ED1100 Grade 1 Panic Rim Device
- TownSteel ED1400 Grade 1 Mortise Panic Device
-
F105.2.2 ASME
The provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches...
-
Problem Four
Problem Four: No sign with the international symbol of accessibility is installed at each accessible parking space....
-
11B-703.7 Symbols of accessibility
Symbols of accessibility, such as the International Symbol of Accessibility (ISA), which are included on signs with raised characters and Braille are not required to be raised....
-
Finish and Contrast: ADA Standard Section 703.7.1
Signs are more legible for persons with low vision when characters contrast as much as possible with their background....
-
11B-703.7.1 Finish and contrast
Signs are more legible for persons with low vision when characters contrast as much as possible with their background....
-
11B-703.6.2 Finish and contrast
Signs are more legible for persons with low vision when characters contrast as much as possible with their background....
-
11B-703.7.1 Finish and contrast
Signs are more legible for persons with low vision when characters contrast as much as possible with their background....
-
11B-703.6.2 Finish and contrast
Signs are more legible for persons with low vision when characters contrast as much as possible with their background....
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Temporary Solutions for Election Day: Accessible Entrance to Polling Place
Suggestion: If another entrance is accessible and on an accessible route from accessible parking, designate it as the accessible entrance and install a directional sign at the main entrance...
-
General: ADA Standard Section 410.1
Section 410.1 of the ADA Standards covers information in the current ADA Standards for platform lifts.