Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
Search Results "Clear Floor Space"
Commonly Searched Documents
-
11B-306.2.4 Additional clearance
-
Chapter 8: Special Rooms, Spaces, and Elements
Chapter 8 covers various types of elements, rooms and spaces, including assembly areas (802), dressing, fitting, and locker rooms (803), kitchens and kitchenettes (804), medical care and...
-
Providing Comforts and Conveniences—Constructed Features
However, if the ground under the element isn't changed, this work doesn't trigger the surface and slope requirements for clear floor and ground space....
-
Are accessible spaces required on all levels of a multi-level parking structure?
If a parking facility has entrances and exits on one level only, standard and van accessible spaces are required on that level so that they are on the shortest accessible route to the entrance...
-
2. Commercial Space
[See subsections ...]
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
Clearances: ADA Standard Section 1003.3
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Accessible Routes
Clear floor space required at play components and maneuvering space can overlap the accessible route. ...
-
Shower Dimensions for ADA
Our financing applications for multifamily residential apartments have the following requirement: “All showers must be 3’ by 5’ and have 36” by 48” parallel approach with clear floor...
-
Minimum Rear Wall Required.
Using the 2010 ADA Standards for Accessible Design, the minimum bench length would be 42" and the width of the clear floor space adjacent to the end of the bench would be 30"....
-
Gurney Accessible Bathroom
Movable wall for shower gurney access Vanity remodeled to clear the space for wheelchair users Hand-held shower 6’ hose on shower Shower heads at four...
-
Chapter 9: Built-In Elements
Changes made to this section include: clarification of provisions for benches concerning clear floor or ground space (903.2), back support (903.4), and height (903.5) addition...
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
9.5 LOCKER ROOMS
., intended for use by people in wheelchairs shall be located no higher than 48 in (1220 mm) above the finished floor....
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...