[2010 ADAS] 2. ...
Search Results "ADA Regulation"
-
11B-213.2 Toilet rooms and bathing rooms
-
Scope of coverage. (Section-by-Section Analysis)
In addition, the Department notes that certain types of facilities, while they may be exempt from the coverage of the ADA, may nonetheless be subject to the accessibility requirements of...
-
Site Selection
Sites constructed after the ADA was passed should generally meet the ADA’s facility standards....
-
11B-403.3 Slope
. ◼ ETA Editor's Note The 2022 CBC Exception at 11B-403.3 is not present in the 2010 ADA Standards....
-
11B-403.3 Slope
. ◼ ETA Editor's Note The 2022 CBC Exception at 11B-403.3 is not present in the 2010 ADA Standards....
-
Basic Principles
The integration of people with disabilities into the mainstream of American life is a fundamental purpose of the ADA....
-
When is accessibility required for a live work conversion project?
for tenant use only QUESTION 1: If no State or federal funding is used and there are no state or federal programs associated with the project am I correct in assuming that no ADA...
-
Elevator requirement to new dining area on the mezzanine of an existing facility
The conversion of bank spaces in a pre-ADA building into a restaurant is clearly an alteration affecting the usability of primary function areas so normally the path of travel obligation...
-
Other specific exclusions
Other specific exclusions The Act states that homosexuality and bisexuality are not impairments and therefore are not disabilities under the ADA....
-
1b
[ADA Standards 4.21.3] Yes __ No __ N/A __ Comments: ________________________________________...
-
4. Faucet Controls
[ADA Stds. 4.21.5] Yes __ No __ N/A __ Comments: _______________________________________...
-
D. Toilet Centerline
[ADA Stds. 4.16.2; 4.17.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
B. Accessible Route
[ADA Stds. 5.3;4.3.8] Yes __ No __ N/A __ Comments: ___________________________________________...
-
M3
[ADA Standards § 4.13.9] Yes No If No, add new accessible hardware or adapt/replace hardware....
-
H27
[ADA Standards § 4.22.4] Yes No...
-
e-ii
[ADA Standards § 4.7.2] Yes No Note: 1:12 is one inch of vertical height for 12 inches of horizontal distance....
-
§ 37.127(c)
(c) Each public entity shall treat as eligible for its complementary paratransit service all visitors who present documentation that they are ADA paratransit eligible, under the criteria...
-
11B-806.2.5 Kitchens, kitchenettes and wet bars
[2010 ADA Standards] 806.2.5 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804....
-
11B-303.2 Vertical
[2010 ADA Standards] 303.2 Vertical. Changes in level of ¼ inch high maximum shall be permitted to be vertical....
-
Section 35.151(b)(3) Alterations to historic facilities
Currently, the regulation provides that alterations to historic facilities shall comply to the maximum extent feasible with section 4.1.7 of UFAS or section 4.1.7 of the 1991 Standards....
-
382.35 May carriers require passengers with a disability to sign waivers or releases?
Carriers must not impose requirements or restrictions on passengers with a disability that they do not impose on other passengers, except where this regulation explicitly permits the carrier...
-
F244.2.1 Alterations and Additions
EXCEPTION: Where an entity is implementing a transition plan for program accessibility developed pursuant to regulations issued under section 504 of the Rehabilitation Act that designates...
-
F245.2.3 Alterations and Additions
EXCEPTION: Where an entity is implementing a transition plan for program accessibility developed pursuant to regulations issued under section 504 of the Rehabilitation Act that designates...
-
R210 Protruding Objects (Section-by-Section Analysis)
other objects that must comply with these requirements, and notes that the AASHTO “Guide for the Planning, Design, and Operation of Pedestrian Facilities” recommends that local governments regulate...