Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...
Search Results "Water Closet Clear Floor Space"
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
-
802.1.2 Width
A single wheelchair space shall be 36 inches (915 mm) wide minimum where two adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (840 mm) wide minimum....
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
Surface Smoothness
The standards limit changes in level and openings in floor and ground surfaces, but they do not further address overall surface smoothness....
-
A4.10.12 Car Controls
In many cases, it will be possible to locate the highest control on elevator panels within 48 in (1220 mm) from the floor....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
TEST NO. 2 – SITE ANALYSIS TEST
In no case shall less than 20 percent of the ground floor dwelling units be on an accessible route and comply with the provisions of Division IV. 3....
-
TEST NO. 2 – SITE ANALYSIS TEST
In no case shall less than 20 percent of the ground floor dwelling units be on an accessible route and comply with the provisions of Division IV....
-
9.5.2(2)(d)
(d) at least one common area which a person with mobility impairments can approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
R304.5.1 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
307.3 Post-Mounted Objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
Additional Transfer Techniques: Use of Stretchers and Gurneys Some equipment, including radiologic equipment, lacks space underneath necessary for a portable floor lift to be used....
-
1017.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less than 36 inches (914 mm)....
-
[ADA Title III §36.403(b)] Primary function
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, and restrooms are not areas containing a primary function...
-
[ADA Title III §36.403(b)] Primary function
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, and restrooms are not areas containing a primary function...
-
Definition of "Mezzanine"
"Mezzanine" is now defined by the same definition used in the IBC: "An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than...
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
Engineered Wood Fiber
The accessibility standards require the minimum 30 x 48 inch clear floor space for transfer to/from the accessible play components have a level surface with less than a 2.08 percent cross...
-
4.10.12(2)
The call button for the main entry floor shall be designated by a raised star at the left of the floor designation (see Fig. 23(a))....
-
§ 38.153(a)
(a) Floor surfaces on aisles, step treads and areas where wheelchair and mobility aid users are to be accommodated shall be slip-resistant....
-
11B-224.1.2 Guest room doors and doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...