Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. EXCEPTIONS: 1....
Search Results "Vertical Actuation Bar"
-
607.4 Grab Bars
-
503.5 Vertical Clearance
503.5 Vertical Clearance....
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Where mirrors or towel bars are provided, no less than one of each shall comply with this section....
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Where mirrors or towel bars are provided, no less than one of each shall comply with this section....
-
Head Room [4.4.2]
Circulation paths must provide at least 80 inches of vertical clearance. Otherwise, fixed barriers detectable by canes must define areas with less clearance....
-
Water closet
Grab bar type and positioning....
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
- Mega Jailhouse Anti-Suicide Grab Bar with Closure Plate 48 inches - Concealed Mounting
- Garaventa Genesis Shaftway - Vertical Platform Lift
-
Grab Bar and Backrest Evaluation
Grab bar and backrest preferences were reported in this study with the tall grab bar and the short backrest being selected more often than the short grab bars and medium and tall backrests...
- Grainger Anti Ligature Grab Bar, SS, 30 In
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
Whitehall Mfg. 24" Grab Bar Flat Closure Plate
Requires the Premium User plan or above. (Login or upgrade your account!)
- Harmar RPL Residential Vertical Platform Lift
- Harmar EPL Enclosed Vertical Platform Lift
- Bobrick 12" Straight Grab Bar B-6806 x 12
-
Water Closet Location and Rear Grab Bar
Water Closet Location and Rear Grab Bar....
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum....