4.20.6 SHOWER UNIT
-
4.20.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
608.2.1 Transfer Type Shower Compartments
608.2.1 Transfer Type Shower Compartments....
-
Grab Bars: ADA Standard Section 607.4
Section 607.4 covers the current ADA Standards for bathtub grab bars.
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4.
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4.
-
217.4.3.2 Private Buildings
Where four or more public pay telephones are provided in a private building, at least one public TTY shall be provided in the building....
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
In the MDE NPRM, the transfer side provision for diagnostic equipment used by patients in the seated position required transfer surfaces to have the option to transfer from a mobility device...
-
Seat Width Evaluation
regardless of the presence or absence of grab bars or a backrest on the transfer surfaces. ...
-
6. Processes for Complying with the ADA
Interested parties, including people with disabilities and organizations representing people with disabilities, must at a minimum have an opportunity to participate in the development of...
-
National Technology Transfer and Advancement Act of 1995
The National Technology Transfer and Advancement Act of 1995 (NTTAA) directs that, as a general matter, all Federal agencies and departments shall use technical standards that are developed...
-
National Technology Transfer and Advancement Act of 1995
The National Technology Transfer and Advancement Act of 1995 (NTTAA) directs that as a general matter, all Federal agencies and departments shall use technical standards that are developed...
-
Leveling: ADA Standard Section 409.4.4
Section 409.4.4 covers the ADA Standards for the self-leveling feature in private residence elevators.
-
Car Controls: ADA Standard Section 409.4.6
Section 409.4.6 covers the current ADA Standards for the car controls in private residence elevators.
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.