Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the transfer...
Search Results "Transfer Support"
-
M305.2.1 Location
-
vii. Ancillary equipment
Ancillary equipment includes items such as positioning straps or cushions; protective padding; adjustable, padded leg supports for gynecological examinations; and additional supports, rails...
-
M305.2.3 Height (Section-by-Section Analysis)
Additionally, for transfer surfaces that are greater than 24 inches deep, the MDE Advisory Committee recommended requiring a positioning support instead of a transfer support, with a height...
-
608.2.1 Transfer Type Shower Compartments
608.2.1 Transfer Type Shower Compartments....
-
Seat Width Evaluation
regardless of the presence or absence of grab bars or a backrest on the transfer surfaces. ...
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
In the MDE NPRM, the transfer side provision for diagnostic equipment used by patients in the seated position required transfer surfaces to have the option to transfer from a mobility device...
-
6. Transfer Surface Height
Transfer Surface Height 6.3 Diagnostic Imaging Equipment Refer to the Rationale found in Section 5.3 for M301.2.1 and to Section 4.3....
-
Transfer Devices for Use with an Amusement Ride
Transfer Devices for Use with an Amusement Ride Transfer devices may also be used to provide access onto an amusement ride....
-
Standing Supports (M304.3 and M305.3)
M305.3 would require the standing supports to provide continuous support throughout the use of the diagnostic equipment and to not rotate within their fittings....
-
11B-1008.3 Transfer systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with Section 11B-1008.3. [2010 ADAS] Advisory 1008.3 Transfer Systems. ...
-
11B-1008.3 Transfer systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with Section 11B-1008.3. [2010 ADAS] Advisory 1008.3 Transfer Systems....
-
11B-1008.3 Transfer systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with Section 11B-1008.3. Advisory 11B-1008.3 Transfer systems....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
M305.2.1 Location
Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position....
-
1014.2.1 Transfer Access
Where transfer access is provided at the entrance to a camp shelter, the entrance shall comply with 1014.2.1....
-
1014.2.1 Transfer Access
Where transfer access is provided at the entrance to a camp shelter, the entrance shall comply with 1014.2.1....
-
106.5.70 Transfer Device
Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat....
-
Transfer Height
Transfer Height Ride seats designed for transfer must be between 14 and 24 inches above the load and unload area surface....
-
Initial Measures and Transfer Setup
However, for the setup of the baseline level transfer (when the person and mobility device were in a position next to platform ready to transfer), if there was a noticeable difference (one...
-
D. M304 Diagnostic Equipment Used by Patients in a Standing Position
There was only one significant change made to the requirement of standing supports on the diagnostic equipment....
-
M304.2.2 Standing Supports (Section-by-Section Analysis)
requirements for standing supports in proposed M305.3....
-
(2) Adjustability: Minimum Low Transfer Height
rights organizations) supported requiring a low transfer height of 17 inches....
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
M301.2 Transfer Surface (Section-by-Section Analysis)
This is an introductory section.