Stair treads shall comply with Section 11B-302. Changes in level are not permitted. Exception: Treads shall be permitted to have a slope not steeper than 1:48.
Search Results "Surface Hazard"
Commonly Searched Documents
-
11B-504.4 Tread surface
-
11B-504.4 Tread surface
Stair treads shall comply with Section 11B-302. Changes in level are not permitted. Exception: Treads shall be permitted to have a slope not steeper than 1:48.
-
Is there a minimum distance between changes in level?
span vertical changes greater than ½”, must have level landings and clearances at the tops and bottoms of each run to provide adequate separation and resting intervals between sloping surfaces...
-
1.2.1 Walks and other non - ramp surfaces
1.2.1 Walks and other non - ramp surfaces. When overall running slope for walks is measured according to Section 1.1.3 a recommended tolerance for running slope is +1%....
-
T302 Walking Surfaces
[See subsections ...]
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction....
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction....
-
Kickplates
Applied kickplates can help protect the door surface. If provided, it is recommended that they cover almost the full door width up to a height of 16 inches from the bottom edge....
-
4.5.4 Gratings
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
4.5.4 GRATINGS
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
11B-705.1.1.3 Color and contrast
Detectable warning surfaces shall comply with Section 11B-705.1.1.3.1. The material used to comply with this section shall be an integral part of the detectable warning surface....
-
Surface and Clear Tread Width on Beach Access Routes
A beach access route must have a firm, stable surface, and have a clear tread width of 60 inches (1,525 millimeters) minimum....
- Playworld® SMARTE Safety Surfacing
-
Approach: ADA Standard Section 904.2
All portions of counters required to comply with 904 shall be located adjacent to a walking surface complying with 403. Advisory 904.2 Approach....
- Unity Surfacing Systems Play-Land Safety Surfacing
-
M304.2 Standing Surface (Section-by-Section Analysis)
The MDE NPRM proposed to require that the standing surface on which patients stand be slip resistant....
-
Floor [1014.3]
The floor surface within a camp shelter must be firm and stable....
-
11B-302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....