Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
Search Results "Stair Nosing"
-
11B-703.5.1 Finish and contrast
-
1022.9 Stairway identification signs
"Floor Identification Signs" are for routine wayfinding use by vision-impaired persons who use the stairs, and these are required at all enclosed stairways of multi-story buildings. ...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
Re: Stair widths
I don't think this is a contradiction, just a higher standard for stairs which need to meet requirements for stairs which are considered part of the accessible means of egress. ...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5. Where pictograms are provided as...
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5. Where pictograms are provided as...
-
F216 Signs
[See subsections ...]
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
11B-703 SIGNS
[See subsections ...]
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
703 Signs
Requirements for signs provide specifications for raised characters (703.2), braille characters (703.3), the height and location of signs with tactile characters (703.4), visual...
-
Mounting Height and Location
Section 703.4 covers the mounting height and location of signs with tactile characters. Such signs are to be mounted so that the tactile elements (raised characters and braille) are...
-
703 Signs
[See subsections ...]
-
216 Signs
Scoping requirements for signs cover room designations (216.2) and directional and informational signs (216.3). The guidelines also include provisions specific to certain elements...
-
1003.2.13.7
[See subsections ...]
-
VI. Interior Signs...
[See subsections ...]
-
11B-216 SIGNS
[See subsections ...]
-
Scoping [4.1.2(7), 4.1.3(16)]
Scoping [4.1.2(7), 4.1.3(16)] Specifications for signage apply according to the type of sign provided. ADAAG does not require building signage except to identify certain...