in accordance with Sections 11B-223 and 11B-805. 11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities....
Search Results "Private Facility"
Commonly Searched Documents
-
11B-223 Medical care and long-term care facilities
-
III-7.8700 Transportation facilities
III−7.8700 Transportation facilities (ADAAG §10). ADAAG provides requirements for bus stops and terminals, rail stations, and airports....
-
Detention/Correctional and Residential Facilities (§203.7 and §203.8)
Detention/Correctional and Residential Facilities (§203.7 and §203.8) Common use spaces in detention/ correctional facilities or residential facilities that do not serve accessible...
-
11B-239 Miniature golf facilities
[See subsections ...]
-
11B-249 Adult changing facilities
[See subsections ...]
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
Sec.36.102(a)(2) Commercial facility
(2) Commercial facility; or...
-
EXISTING BUILDING OR FACILITY
EXISTING BUILDING OR FACILITY....
-
11B-202 EXISTING BUILDINGS AND FACILITIES
11B-202 Existing buildings and facilities...
-
§104.33(c)(4) Placement of handicapped persons by parents
conformance with the requirements of this section and §104.34, a free appropriate public education to a handicapped person and the person's parents or guardian choose to place the person in a private...
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
409.4.6 Car Controls
Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305.
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1.
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a of 1/2 inch (13 mm) under rated loading to zero loading conditions.