Handrails, stanchions, or handholds shall be provided within small non-rail vehicles in a configuration that permits onboard circulation and assistance with seating and standing....
Search Results "Overhead Handrail"
Commonly Searched Documents
-
T207.4.1. Small vehicles
-
R409.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 32 mm (1.25 in) minimum and 51 mm (2 in) maximum....
-
4.26.4 Eliminating Hazards
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
4.26.4 ELIMINATING HAZARDS
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
§ 38.97(c)
(c) At entrances equipped with steps, handrails or stanchions shall be provided in the entrance to the car in a configuration which allows passengers to grasp such assists from outside the...
-
T303.2 Edges
Edges shall be rounded or eased.
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
M301.4 Lift Compatibility
Overhead lifts are already currently installed as accessories for some imaging systems. Overhead lifts are not possible to be used in the MR exam room due to the magnetic fields....
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance
-
Stair widths
Section 1009.3 states that in order to be a part of the accessible means of egress between stories, stairs shall have a clear width of 48" BETWEEN the handrails....
-
Aisle Ramps in Assembly Areas
In assembly areas, aisle ramps required to be accessible are exempt from some handrail requirements....
-
§ 38.155 Interior circulation, handrails and stanchions
[See subsections ...]
-
Landings [§405.7]
Handrails, edge protection, vertical posts and other elements cannot obstruct or overlap the minimum 60” by 60” clearance....
-
3. Lift Compatibility Exception
The final commenter, a manufacturer, opposed the exemption unless the overhead lift was included as part of the equipment when sold....
-
§ 38.29(d)
(d) Handrails and stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with disabilities....
-
§ 38.29(a)
(a) Interior handrails and stanchions shall permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to reach a securement location from the lift or ramp....
-
11B-405.8 Handrails
Ramp runs shall have handrails complying with Section 11B-505. [2010 ADAS] 405.8 Handrails. ...
-
11B-405.8 Handrails
Ramp runs shall have handrails complying with Section 11B-505. [2010 ADAS] 405.8 Handrails....
-
11B-405.8 Handrails
Ramp runs shall have handrails complying with Section 11B-505. [2010 ADA Standards] 405.8 Handrails....
-
R409.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 100 mm (4 in) minimum and 160 mm (6.25 in) maximum, and a cross-section dimension of 57 mm...