Section 403.5.1 covers the current ADA Standards for the clear width of walking surfaces that are part of an accessible route.
Search Results "Lavatory Clear Floor Space"
Commonly Searched Documents
-
Clear Width: ADA Standard Section 403.5.1
-
4.2.4.1 Size and Approach
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair and occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....
-
Accessible Miniature Golf Course Holes
Sections 239.2 and 1007.3 of the 2010 Standards require at least fifty percent (50%) of golf holes on miniature golf courses to be accessible, including providing a clear floor or ground...
-
Space Needs
Percentage of subjects who were able to transfer within each clear floor space dimension for Protocol A transfer TO and FROM the platform at their maximum height (Max) and minimum height...
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302....
-
A4.23.3 Clear Floor Space
Since the shower does not have a lip, the floor space can be used for required maneuvering space....
-
§ 38.83(a)(1) General
plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear...
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates.
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
Beds: ADA Standard Section 224.3
Section 224.3 covers scoping requirements in the current ADA Standards for transient lodging guest room beds.
-
Forward Approach
Forward Approach Knee and toe clearances specified for lavatories in 4.19, which recognize space for plumbing (see page 75), can be applied to sinks....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
1134A.8, Item 4
Knee and toe space. Knee and toe space shall be provided by one of the following:...
-
1134A.8, Item 4
Knee and toe space. Knee and toe space shall be provided by one of the following:...