A clear floor or ground space of 36 inches (915 mm) by 48 inches (1220 mm) shall be located at an end the bench with one side of the space adjoining an accessible route, outdoor recreation...
Search Results "Lavatory Clear Floor Space"
-
4.4.4 Clear Floor or Ground Space
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
- McGuire Manufacturing Co., Inc. 155WC: Offset Lavatory Strainer
- Figure 604.3.1 Size of Clearance at Water Closets – Drawing from the U.S. Access Board
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
Clearance: ADA Standard Section 604.9.2
Section 604.9.2 covers the current ADA Standards for clearances around children's use water closets.
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
- McGuire Manufacturing Co., Inc. ProDrainWC: Lavatory Strainer Less Overflow
-
305.2 Floor or Ground Surfaces
305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted....
-
Call Button Clear Floor Space
...are all of the elevator lobbies free of ash trays or other elements placed below the elevator call buttons that project more than 4"? [ADA Stds. 4.10.3] Yes __ No __ N/A __...
-
4.2.6 Clear Floor or Ground Space
At least 48 inches (1220 mm) by 48 inches (1220 mm) of clear floor or ground space shall be provided on all usable sides of fire rings, grills, fireplaces or woodstoves....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...
-
Forward and Side Approaches
At most elements, clear floor space can be positioned for either a forward approach or a side approach....
- Neo-Metro Urinal Divider Number 8949-N
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted....
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....