Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
Search Results "Grade Level Exit"
-
Accessible Routes: ADA Standard Section 1008.2
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
T502.3 Doorways with Level Boarding
Doorways on non-rail vehicles designed for level boarding bus systems shall comply with T502.3....
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
Which Paths Are Usable Circulation Paths?
Directional sound is an audible signal that leads people to safety in a way that conventional alarms cannot, by communicating the location of exits using broadband noise....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
2) Where the Standard says "Changes in level are not permitted"
2) Where the Standard says "Changes in level are not permitted", such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this...
-
4.1.1(3) Areas Used Only by Employees as Work Areas
Areas that are used only as work areas shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas....
- BrailleWorks
-
4.3.11.1(6)
The area or room shall be provided with an exit directly to an exit enclosure....
-
Floor or Ground Surfaces: ADA Standard Section 304.2
Section 304.2 covers the current ADA Standards for the ground surfaces of a turning space.
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
Examples include exit-only doors with no operating hardware on the exterior side or separate enter and exit fare gates in transit stations....
-
1009.2 Continuity and components
Exterior exit stairways complying with Sections 1009.3 and 1027 and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable and serving levels other than...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
206.2.17.1 Ground Level and Elevated Play Components
206.2.17.1 Ground Level and Elevated Play Components. At least one accessible route shall be provided within the play area....
-
§ 38.91(c)(1)
(1) Commuter rail cars shall comply with §§38.93(d) and 38.109 of this part for level boarding unless structurally or operationally impracticable....