Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall...
Search Results "Grab Bar Clearance"
-
11B-604.5.2 Rear wall
-
28.1 Q. If an architect or builder chooses to follow the bathroom specifications in Requirement 7...are the other bathrooms in the dwelling unit required to have reinforced walls for grab bars?
Requirement 6 of the Guidelines requires reinforced walls in bathrooms for later installation of grab bars....
-
609.5 Surface Hazards
Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-609.5 Surface hazards
Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges....
-
604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
Bobrick Straight Grab Bar B-5806 Details
Requires the Premium User plan or above. (Login or upgrade your account!)
-
604.9.6 Dispensers
There shall be a clearance of 1 1/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 11/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
- Figure 1009.5.7 Grab Bars – Drawing from the U.S. Access Board
- Gamco Swing Up Grab Bar - 125-Swing-Up
-
609.2 Cross Section
Grab bars shall have a cross section complying with 609.2.1 or 609.2.2....
-
609.2 Cross Section
Grab bars shall have a cross section complying with 609.2.1 or 609.2.2....
-
609.2 Cross Section
Grab bars shall have a cross section complying with 609.2.1 or 609.2.2....
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-609.2 Cross section
Grab bars shall have a cross section complying with Section 11B-609.2.1 or 11B-609.2.2....
-
609.2 Cross Section
Grab bars shall have a cross section complying with 609.2.1 or 609.2.2....
-
11B-609.2 Cross section
Grab bars shall have a cross section complying with Section 11B-609.2.1 or 11B-609.2.2....
-
11B-609.2 Cross section
Grab bars shall have a cross section complying with Section 11B-609.2.1 or 11B-609.2.2....
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 148 Front Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...