If the voting area is not on the same level as the entrance, there must be an independently operable elevator or lift to provide an accessible route to individuals with disabilities....
Search Results "Elevator Bank"
Commonly Searched Documents
-
Lifts and Elevators
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
Platform to Hoistway Clearance: ADA Standard Section 407.4.3
Section 407.4.3 covers the current ADA Standards for the required clearance between the elevator car platform and the hoistway landing.
-
General: ADA Standard Section 409.1
Section 409.1 of the ADA Standards covers information in the current ADA Standards for private residence elevators.
-
11B-240.2.2 Elevated play components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with Section 11B-1008.4....
-
11B-240.2.2 Elevated play components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with Section 11B-1008.4....
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational....
-
11B-240.2.2 Elevated play components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with Section 11B-1008.4....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in elevator cars....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2.
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable.
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
-
11B-407.4.10.2 Surfaces
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
-
11B-407.4.7.1 Buttons
Car control buttons shall comply with Section 11B-407.4.7.1.
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation. Signs shall be...