The operable parts of outdoor constructed features, such as handles, levers, and latches, must comply with the technical requirements of sections 309.3 and 309.4 of the ABA Standards...
Search Results "Door Operator"
-
Operable Parts [1011.3]
-
404.2.8.1 Door Closers and Gate Closers
404.2.8.1 Door Closers and Gate Closers....
-
409.3 Elevator Doors
409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
4.23.2 Doors
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
-
4.23.2 DOORS
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). gg....
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
- SafeZone: Norton Factory Video 7 22 14
-
2010 ADA Standards - Plan Review Tool - Doors
2010 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (258 KB) Click here to view/download the pdf, Page 2 of 2 (264 KB) * * * * * * *...
-
4.3.9 DOORS
Doors along an accessible route shall comply with 4.13....
-
4.3.9 Doors
Doors along an accessible route shall comply with 4.13....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
M307.3 Operation
Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
M307.3 Operation
Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
Doors
[See subsections ...]
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
- Norton Surface Mounted 7100SZ Series SafeZone® Electromechanical Closer
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....