All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
Search Results "Door Closing Speed"
Commonly Searched Documents
- 
    
  
  4.22.2 Doors
  
- 
    
  
  4.22.2 DOORS
  All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture.... 
- 
    
  
  11B-407.3.4 Door and signal timing
  The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/... 
- 
    
  
  11B-407.3.4 Door and signal timing
  The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/... 
- 
    
  
  404 Doors, Doorways, and Gates
  Changes made to the requirements for manually operated doors: clarify coverage of gates and the application of this section to manual doors and doorways intended for user passage... 
- 
    
  
  2.2.6 Door Use
  Door type Door 1 Door 2 Door 3 Clear opening 825 mm 1040 mm 755 mm Closer No No Yes Resistance... 
- 
    
  
  402 Closed Functionality
  [See subsections ...] 
- 
    
  
  402 Closed Functionality
  [See subsections ...] 
- 
    
  
  4.13.7 Two Doors in Series
  The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space.... 
- 
    
  
  4.13.7 TWO DOORS IN SERIES
  The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space.... 
- 
    
  
  R218 Doors, Doorways, and Gates
  R218 Doors, Doorways, and Gates. Where provided at pedestrian facilities, doors, doorways, and gates shall comply with section 404 of Appendix D to 36 CFR part 1191.... 
- 
    
  
  11B-604.8.1.1.1 Maneuvering space with in-swinging door
  In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance... 
- 
    
  
  11B-407.3.4 Door and signal timing
  The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/... 
- 
    
  
  408.3.2 Swinging Doors
  408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2.... 
- 
    
  
  SECTION 1010 DOORS, GATES AND TURNSTILES
  [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for... 
- 
    
  
  Door and Gate Surfaces [§404.2.10]
  Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”.... 
- 
    
  
  Common Problems with Entrances and Doors
  Common Problems with Entrances and Doors Ø Each leaf of a set of double doors is often too narrow to be used independently by someone who uses a wheelchair.... 
- Jacknob Corp. 7033 Surface Mounted Self-Closing Hinge Set
- 
    
  
  1132A.2 Interior doors and secondary exterior doors
  1132A.2 Interior doors and secondary exterior doors.... 
- 
    
  
  Doors [4.13]
  [See subsections ...] 
- 
    
  
  H. Stall Door
  If the accessible toilet is in a stall, is the stall door positioned diagonally opposite, not directly in front of, the toilet so persons who use wheelchairs may pull fully into the stall... 
- 
    
  
  C. Door Hardware
  Is the door hardware (lever, pull, panic bar, etc.) usable with one hand, without tight grasping, pinching or twisting of the wrist, since many persons with disabilities may not have high... 
- 
    
  
  4.17.5* Doors
  Toilet stall doors, including door hardware, shall comply with 4.13.... 