SPECIFICATIONS: FRAME: All welded steel frame fabrication: seat/back support channel is die-formed from 1/8" thick (11 ga.) steel, frame post and portable/surface mount foot are made using...
Search Results "CSI: Construction Specification Institute"
- Pilot Rock Bench B110C with Full-length Grab Bar
-
7.4.8 Protruding Objects
Constructed features, including signs, shall not extend into the trail tread more than 4 inches (100 mm) between 27 inches (685 mm) and 80 inches (2030 mm) above the surface of the trail...
-
11B-809.8 Doors
Doors to small mechanical closets specifically dedicated to furnaces or hot water heaters shall not be required to comply with this section....
-
6.11 Protruding Objects
Constructed features, including signs, shall not extend into the space above a beach access route more than 4 inches (100 mm) if they are between 27 inches (685 mm) and 80 inches (2030...
-
Definitions of Standards Referenced in This Notice
In this notice, we explain our interpretation of 34 CFR 104.23 as it relates to new construction and alterations commenced on or after September 15, 2010....
-
Revised and New Standards for Buildings and Facilities
The 2010 ADA Standards for Accessible Design include revised and new minimum requirements for newly and constructed or altered facilities so that they are accessible to and usable by individuals...
-
VII. New Construction and Alterations
Public entities must ensure that newly constructed buildings and facilities are free of architectural and communication barriers that restrict access or use by individuals with disabilities...
-
3.4.2 ORARs in Viewing Areas
Connections shall be provided between site furnishings and constructed features in viewing areas as well as between accessible viewing areas, parking areas, and accessible common use features...
- Landscape Forms Inc. Olithas Outdoor Bench
- Landscape Forms Inc. Plexus Bench Collection
-
201.1 Scope
All areas of newly designed and newly constructed buildings and facilities and altered portions of existing buildings and facilities shall comply with these requirements....
- Landscape Forms Inc. Parallel 42 Bench Collection
-
Camping and Picnic Facilities [F244.2.3.1, F244.3, F245.2.5.1, and F244.5.3]
Within camping and picnic units with mobility features (figure 16), at least one of each type of outdoor constructed feature must comply with the applicable technical requirements for the...
-
§40.4 Standards.
Residential structures subject to this part shall be designed, constructed or altered to ensure that physically handicapped persons have access to, and use of, these structures....
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4. Advisory 11B-202.2 Additions....
-
Sec.36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992...
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. Where possible, drainage...
-
§ 35.151(c) Accessibility standards
(c) Accessibility standards.
-
Requirements to Remember for: Light Rail Projects
[See subsections ...]
-
Public entrances
Sixty percent of all public entrances to the facility must be accessible. If there are only two entrances, both must be accessible. (DOT ADA Standard 206.4.1.)
-
ADA & Level Boarding - Perfromance [sic] Standards on Station-by-Station Basis
49 CFR §37.42(d)(2) DECEMBER 14, 2011
-
§ 36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992...
-
1011.2.4 Openings
This section requires openings in the clear ground space such as drainage grates to not allow passage of a sphere more than 1/2 inch in diameter. Where possible, drainage grates...
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. Where possible, drainage...