  707.5.1 User Control
  
- 
    
  
  402.2.4 User Control
  Speech output for any single function shall be automatically interrupted when a transaction is selected. Speech output shall be capable of being repeated and paused. 
- Accessibility Management Platform (AMP) for Mobile Accessibility Tool by SSB BART Group
- 
    
  
  Location
  Source: NCHRP Web Only Document 117-A, Accessible Pedestrian Signals: A Guide to Best Practice, Figure 6-8 Figure 4: Installation of APS on two separated poles, aligned with crosswalk... 
- 
    
  
  ACCESSIBLE MEANS OF EGRESS
  A continuous and unobstructed way of egress travel from any accessible point in a building or facility to a public way. [2010 ADA Standards 106.5] Accessible Means of Egress.... 
- 
    
  
  11B-408.4.6 Car controls
  Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.... 
- 
    
  
  11B-408.4.6 Car controls
  Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.... 
- 
    
  
  11B-408.4.6 Car controls
  Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.... 
- 
    
  
  704.3 Volume Control Telephones
  704.3 Volume Control Telephones. Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum.... 
- 
    
  
  1011.3 Operable Parts
  Exception 2 requires trash and recycling receptacles with hinged lids and controls to keep out large animals to comply with the technical requirements for operation in 309.4 of the Architectural... 
- 
    
  
  11B-203.4 Limited access spaces
  Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible... 
- Figure 604.8.2 Ambulatory Accessible Toilet Compartment – Drawing from the U.S. Access Board
- 
    
  
  11B-604.8.1 Wheelchair accessible compartments
  Wheelchair accessible compartments shall comply with Section 11B-604.8.1.... 
- 
    
  
  11B-604.8.2 Ambulatory accessible compartments
  Ambulatory accessible compartments shall comply with Section 11B-604.8.2.... 
- 
    
  
  704.3 Volume Control Telephones
  Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum.... 
- 
    
  
  11B-707.5.1 User control
  11B-707.5.1 User control. Speech shall be capable of being repeated or interrupted. Volume control shall be provided for the speech function.... 
- 
    
  
  R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons (Section-by-Section Analysis)
  R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons (Section-by-Section Analysis) An accessible pedestrian signal and pedestrian pushbutton is an integrated device that communicates... 
- 
    
  
  704.3 Volume Control Telephones
  Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum.... 
- 
    
  
  Delta 3-Setting 2-Port Diverter Trim - Model T11859
  Requires the Premium User plan or above. (Login or upgrade your account!)
- 
    
  
  Delta 3-Setting 2-Port Diverter Trim - Model T11861
  Requires the Premium User plan or above. (Login or upgrade your account!)
- 
    
  
  Delta 3-Setting 2-Port Diverter Trim - Model T11864
  Requires the Premium User plan or above. (Login or upgrade your account!)
- 
    
  
  Length: ADA Standard Section 503.3.2
  Section 503.3.2 covers the current ADA Standards for the required length of access aisles at passenger loading zones. 
- 
    
  
  Width: ADA Standard Section 503.3.1
  Section 503.3.1 covers the current ADA Standards for the required width of access aisles at passenger loading zones. 
- 
    
  
  A4.16.5 Flush Controls
  Flush controls for tank-type toilets have a standardized mounting location on the left side of the tank (facing the tank).... 