Search Results "Stairway"
Commonly Searched Documents
- Balco Inc. IllumiTread Photoluminescent Egress Markings System Section
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons....
-
11B-504 STAIRWAYS
[See subsections ...]
-
11B-504 Stairways.
[See subsections ...]
-
11B-504 Stairways
[See subsections ...]
-
STAIRWAY
One or more flights of stairs, either exterior or interior, with the necessary landings and platforms connecting them, to form a continuous and uninterrupted passage from one level...
-
STAIRWAY
One or more flights of stairs, either exterior or interior, with the necessary landings and platforms connecting them, to form a continuous and uninterrupted passage from one level...
-
210 and 504 Stairways
210 and 504 Stairways The 1991 Standards require stairs to be accessible only when they provide access to floor levels not otherwise connected by an accessible route (e.g., where the...
-
STAIR
A change in elevation, consisting of one or more risers.
-
SECTION 1009 STAIRWAYS
SECTION 1009 STAIRWAYS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
11B-504.3 Open risers
Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread....
-
1007.3 Stairways
1007.3 Stairways. ...
-
4.3.11.3* Stairway Width
Each stairway adjacent to an area of rescue assistance shall have a minimum clear width of 48 inches between handrails....
-
210 Stairways
210 Stairways...
-
R216 Stairways and Escalators.
R216 Stairways and Escalators....
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
Open Risers: ADA Standard Section 504.3
Section 504.3 covers the current ADA Standards for open risers on stairways.
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....
-
1009.3.3 Area of Refuge
Areas of refuge are not required at stairways serving open parking garages....
-
1009.3 Stairways
Exit access stairways that connect levels in the same story are not permitted as part an accessible means of egress....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....
-
R408.1 General
Stairways shall comply with R408....
-
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS...