Search Results "Signage"
Commonly Searched Documents
-
A.4.30 SIGNAGE
-
4.1.2(7) Building Signage
(7) Building Signage. Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6....
-
D. Signage
Signage (1) Defendants will install directional signage to indicate accessible entrances, and the routes from inaccessible entrances to designated accessible entrances....
-
INFORMATION AND SIGNAGE {35.163}
INFORMATION AND SIGNAGE {35.163} “A public entity shall ensure that interested persons, including persons with impaired vision or hearing, can obtain information as to the existence and...
- Takeform Fusion Signage Overheads Type C.2
-
§35.163 Information and signage
§35.163 Information and signage....
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Signs: ADA Standard Section 703
[See subsections ...]
-
Signs: ADA Standard Section 216
Section 216 covers scoping requirements in the current ADA Standards for signs.
-
11B-216 Signs
[See subsections ...]
-
11B-703 Signs
[See subsections ...]
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
ETA Summary of ADA Signage Requirements
Summary of ADA Signage Requirements Click here to view/download the pdf version (162 KB)....
-
§35.163 Information and Signage
§35.163 Information and Signage Section 35.163(a) requires the public entity to provide information to individuals with disabilities concerning accessible services, activities, and facilities...
-
11B-216.1 General
The substantive difference between the CBC and 2010 ADA Standards scoping for signage at parking facilities is that signs identifying permanent rooms and spaces, directional and informational...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface...
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum. Vertices shall be radiused between 1/8 inch (3.2 mm) minimum and ¼ inch...
-
11B-502.6.2 Minimum fine
Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250.”
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2.
-
Temporary Signage
Temporary Signage Temporary signs, which are exempt, include identification of tenancies, names and titles of room occupants, non-fixed signage and temporary postings ("Out of Service...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
ETA Summary of ADAAG/CBC Signage Requirements
ADAAG/CBC Signage Requirements Click here to view/download the pdf version (1.22 MB)...
-
IV. Priority Seating Signs and Other Signage
Priority Seating Signs and Other Signage...