Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
Search Results "Shower Curb"
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
-
Transfer Type Shower Compartments: ADA Standard Section 608.3.1
Section 608.3.1 covers the current ADA Standards for grab bars in transfer type shower compartments.
-
Size and Clearances for Shower Compartments: ADA Standard Section 608.2
Section 608.2 covers the current ADA Standards for the size and clearances of shower compartments.
-
Shower Compartments: ADA Standard Section 608
Section 608 covers the current ADA Standards for shower compartments.
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.2.2
Section 608.2.2 covers the current ADA Standards for the size of standard roll-in type shower compartments.
- Collapsible Water Retainer Shower Dam for Shower Threshold Information Video
- Collapsible Water Retainer Shower Dam for Shower Threshold
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.2.3
Section 608.2.3 covers the current ADA Standards for the size and clearances of alternate roll-in type shower compartments.
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
- NewVision™ Curb Ramp Inventory System (NVCRIS)
-
Curb or Barrier: ADA Standard Section 1005.3.1
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (76 mm) of the compartment entry....
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (76 mm) of the compartment entry....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....