Search Results "Private Residence Elevator"
-
206 and Chapter 4 Accessible Routes
-
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators....
-
Elevators and Platform Lifts
-
Private Residence Elevators [§409]
Private Residence Elevators [§409] Private residence elevators are permitted only within a residential dwelling unit or in a multiple dwelling unit facility as a means of access to a...
-
Common Questions (Elevators and Platform Lifts)
Common Questions
-
409 Private Residence Elevators
409 Private Residence Elevators...
-
409.1 General
Private residence elevators that are provided within a residential dwelling unit required to provide mobility features complying with 809.2 through 809.4 shall comply with 409 and with ASME...
-
409.2 Call Buttons
409.2 Call Buttons. Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309.
-
409.3 Elevator Doors
409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
409.4 Elevator Cars
409.4 Elevator Cars. Private residence elevator cars shall comply with 409.4....
-
409.4.1 Inside Dimensions of Elevator Cars
409.4.1 Inside Dimensions of Elevator Cars. Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
409.4.3 Platform to Hoistway Clearance
409.4.3 Platform to Hoistway Clearance. The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
409.4.4 Leveling
409.4.4 Leveling. Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
-
409.4.5 Illumination Levels
Elevator car illumination shall comply with 407.4.5....
-
409.4.6 Car Controls
Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush....
-
409.4.6.1 Size
409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
409.4.6.2 Location
Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
409.4.7 Emergency Communications
409.4.7 Emergency Communications. Emergency two-way communication systems shall comply with 409.4.7.
-
409.4.7.1 Type
409.4.7.1 Type. A telephone and emergency signal device shall be provided in the car.
-
409.4.7.2 Operable Parts
409.4.7.2 Operable Parts. The telephone and emergency signaling device shall comply with 309.3 and 309.4.
-
409.4.7.3 Compartment
409.4.7.3 Compartment. If the telephone or device is in a closed compartment, the compartment door hardware shall comply with 309.