Automatic doors and automatic gates shall comply with 404.3....
Search Results "Power Assisted Door"
-
404.3 Automatic and Power-Assisted Doors and Gates
-
404.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with 404.2.5.
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates....
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates....
-
Thresholds: ADA Standard Section 404.3.3
Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates....
-
Doors in Series and Gates in Series: ADA Standard Section 404.3.4
Section 404.3.4 covers the current ADA Standards for doors in series and gates in series at automatic and power-assisted doors and gates....
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates....
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
Revolving Doors, Revolving Gates, and Turnstiles: ADA Standard Section 404.3.7
Section 404.3.7 covers the current ADA Standards for revolving doors, revolving gates, and turnstiles.
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates....
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates. ...
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates. ...
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates. ...
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....