Two exits or exit access doorways from any space shall be provided where one of the following conditions exists: The occupant load of the space exceeds the values in Table 1004.2.1...
Search Results "Occupant Load"
-
1004.2.1 Exit or exit access doorways required
-
§ 38.23(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds....
-
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
412.2 Airport traffic control towers. …
-
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
412.2 Airport traffic control towers. …
-
SECTION 111 CERTIFICATE OF OCCUPANCY
[See subsections ...]
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors by...
-
1017.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less than 36 inches (914 mm)....
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less than that required for corridors by...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
4.1.4 OCCUPANCY CLASSIFICATIONS
Buildings and facilities shall comply with these standards to the extent noted in this section for various occupancy classifications, unless otherwise modified by a special application section...
-
Load and Unload Areas: ADA Standard Section 1002.3
A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas....
-
11B-405.5 Clear width
The clear width of ramps in residential uses serving an occupant load of fifty or less shall be 36 inches (914 mm) minimum between handrails....
-
11B-405.5 Clear width
The clear width of ramps in residential uses serving an occupant load of fifty or less shall be 36 inches (914 mm) minimum between handrails....
-
1007.6.1 Size
Each area of refuge shall be sized to accommodate one wheelchair space of 30 inches by 48 inches (762 mm by 1219 mm) for each 200 occupants or portion thereof, based on the occupant load...
-
1003.2.13.5.1 Size
Each area of refuge shall be sized to accommodate one wheelchair space of 30 inches (762 mm) by 48 inches (1219 mm) for each 200 occupants or portion thereof, based on the occupant load...
-
§100.301(b)
(b) Nothing in this part limits the applicability of any reasonable local, State, or Federal restrictions regarding the maximum number of occupants permitted to occupy a dwelling....
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION ETA Editor's Note California Building Code Chapter 3 - Use and Occupancy Classification, not adopted by Division of the State Architect...
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
ETA Editor's Note California Building Code Chapter 3 - Use and Occupancy Classification, is not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and has...
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
ETA Editor's Note California Building Code Chapter 3, Use and Occupancy Classification, is not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and has...
-
1007.6.1 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
1009.6.3 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
1009.6.3 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY ETA Editor's Note Sections from California Building Code Chapter 4 not adopted by Division of the State Architect...