This initial obligation does not apply to Departments where the examination tables are physically integrated with medical technologies (e.g., radiology or other imaging equipment); the need...
Search Results "Imaging Bed"
Commonly Searched Documents
-
IV. ACCESSIBLE MEDICAL EQUIPMENT
- Merlexi Craft™ Liberty MRI Wheelchairs
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
224.3 Beds
224.3 Beds. In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
-
F224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
-
224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
- Sizewise Evolution
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
beds, or stretchers and therefore should be subject to the same transfer surface size requirement....
-
§ 1194.21(e)
(e) When bitmap images are used to identify controls, status indicators, or other programmatic elements, the meaning assigned to those images shall be consistent throughout an application...
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
- Quadraplegic Transfer
-
A. Final Regulatory Assessment (EO 13563 and EO 12866)
Examples of such diagnostic equipment include examination tables and chairs, weight scales, mammography equipment, and other imaging equipment....
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Accessibility Standards for Medical Diagnostic Equipment Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations - Imaging Equipment Final Report June...
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
In these cases, a ceiling-mounted lift may be a better method for some types of imaging equipment because the portable lift would need to access the diagnostic imaging table from the side...
-
4.3.2 Transfer Surfaces and Imaging Equipment Functions
4.3.2 Transfer Surfaces and Imaging Equipment Functions The transfer surface (table) of diagnostic imaging equipment serves two purposes: (1) it allows patients to be positioned properly...
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment....