Simplified ADA Handrail Why Choose a Simplified ADA Handrail? The Simplified ADA handrail system is made up of modular components....
Search Results "Handrail"
Commonly Searched Documents
- Simplified Building Concepts ADA Handrail
-
Handrail Gripping Surfaces: ADA Standard Section 1008.2.5.3.1
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
- HEWI System Lignum Handrails
- HEWI System Color Handrails
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
- HEWI System Circum Handrails
- Kee Safety Inc. ADA Safety Handrail Components
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10 Handrail extensions
In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers...
- HEWI System Lignum Multiplex Handrails
- HEWI System Lignum Protect Handrails
-
11B-505.9 Fittings
Handrails shall not rotate within their fittings....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....
- Inpro Corporation IPC® 940 Smooth Handrail with Reveal
- Inpro Corporation IPC® 900 Handrail
-
General: ADA Standard Section 505.1
Section 505.1 of the ADA Standards covers information in the current ADA Standards for handrails.
- Inpro Corporation IPC® 2000 Handrail
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
- Inpro Corporation IPC® HR9 Northern Hardwoods® Real Wood Handrail