(4) Gripping surfaces shall be continuous....
Search Results "Gripping Surface"
Commonly Searched Documents
-
4.8.5(4)
-
4.9.4(4)
(4) Gripping surfaces shall be uninterrupted by newel posts, other construction elements, or obstructions....
-
505.8 Surfaces
505.8 Surfaces. Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
Sections 4.8.5 and 4.9.4
Section 505.3 of the 2010 Standards sets technical requirements for continuity of gripping surfaces....
-
1008.2.5.3.1 Handrail Gripping Surfaces
1008.2.5.3.1 Handrail Gripping Surfaces....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
3.3.14 Grip Strength
In particular, the magnitude of maximum power grip forces was noticeably greater in a power grip than in a pinch grip....
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
2.2.5 Grip Strength
2.2.5 Grip Strength Four types of grip strength measurements for the dominant hand were assessed....
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
-
Handrails [ADA Standards §504.6, §505]
Handrails [ADA Standards §504.6, §505] Specifications in the ADA Standards for handrail surfaces and clearances facilitate a power grip along the handrail length....
-
Surface: ADA Standard Section 810.2.1
Bus stop boarding and alighting areas shall have a firm, stable surface....
-
Floor or Ground Surface: ADA Standard Section 403.2
Section 403.2 covers the current ADA Standards for floor or ground surfaces that are part of an accessible route.