308.2.2 Obstructed High Reach....
Search Results "Functional Reach"
Commonly Searched Documents
-
308.2.2 Obstructed High Reach
-
308.2.2 Obstructed High Reach
The high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum....
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
Obstructed High Reach
The maximum high reach is reduced to 46” when the reach over an obstruction is deeper than 10” (to a maximum of 24”)....
-
3.3.15.2 Side (lateral) reach - unobstructed
3.3.15.2 Side (lateral) reach - unobstructed For WhMD users in our study that could perform a reach task, over 90% of each of the WhMD user groups could reach beyond the lateral most...
-
Reach Ranges and Operability Requirements
Design Tip Understand forward reach and side reach terminology....
-
308.2 Forward Reach
308.2 Forward Reach...
-
ACCESSIBILITY FUNCTION BUTTON
[DSA-AC] A button on an elevator hall call console in a destination-oriented elevator system that when pressed will activate a series of visual and verbal prompts and announcements...
-
Forward Reach [§308.2]
Forward Reach [§308.2] The range for unobstructed reaches (15” – 48”) applies only to those portions of elements that are operable....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
R406.2 Unobstructed Forward Reach
R406.2 Unobstructed Forward Reach....
-
R406.3 Unobstructed Side Reach
R406.3 Unobstructed Side Reach....
-
3.3.15.1 Forward reach – unobstructed
3.3.15.1 Forward reach – unobstructed A large percentage of WhMD users in our study could not reach beyond the most forward point of their WhMDs or foot, and the difference between users...
-
Side Reach Radius
Elements located in corners can be difficult to reach from a side approach....
-
Side Reach [§308.3]
Side Reach [§308.3] The range for side reach, like forward reach is 15” to 48” if unobstructed....
- Figure 308.2.1 Unobstructed Forward Reach – Drawing from the U.S. Access Board