Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
Search Results "Floor Button"
-
407.4.6.2 Buttons
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309....
-
Floor or Ground Surface: ADA Standard Section 403.2
Section 403.2 covers the current ADA Standards for floor or ground surfaces that are part of an accessible route.
-
Floor or Ground Surfaces: ADA Standard Section 305.2
Section 305.2 covers the current ADA Standards for floor or ground surfaces of clear floor or ground space.
-
Clear Floor Space: ADA Standard Section 410.3
Section 410.3 covers the current ADA Standards for clear floor space in platform lifts.
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
Car Controls [4.10.12]
Control panels must be located so that no floor button is higher than 54 inches for a side reach and 48 inches for a front approach....
-
Clear Floor Space: ADA Standard Section 605.3
Section 605.3 covers the current ADA Standards for urinal clear floor space.
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
Clear Floor Space: ADA Standard Section 309.2
Section 309.2 covers the current ADA Standards for clear floor space at operable parts.
-
Floor or Ground Surfaces: ADA Standard Section 302
Section 302 covers the current ADA Standards for floor or ground surfaces.
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
4.10.12(4)
(4) Location. Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors...
-
4.10.12(4)
(4) Location. Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors...
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
-
11B-407.2.1.2 Size and shape
The buttons shall be activated by a mechanical motion that is detectable. [2010 ADA Standards] 407.2.1.2 Size....