Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of car devices provided they meet the displacement requirements of paragraph (c)(...
Search Results "Floating Bridge"
-
§ 38.95(c)(6)(ii) Exception
-
§ 38.83(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches, with a safety factor...
-
§ 38.83(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridges plates stowed in the passenger...
-
1003.2 Accessible Routes
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Chapter 4 except as modified by the exceptions in 1003.2....
-
1003.2 Accessible Routes
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Chapter 4 except as modified by the exceptions in 1003.2....
-
§ 38.73(d)(4) Exception
the horizontal or vertical requirements of paragraphs (d) (1), (2) or (3) of this section, platform or vehicle devices complying with §38.83(b) or platform or vehicle mounted ramps or bridge...
-
11B-1003.2 Accessible routes
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Division 4 except as modified by the exceptions in Section 11B-1003.2....
-
11B-1003.2 Accessible routes
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Division 4 except as modified by the exceptions in Section 11B-1003.2....
-
11B-1003.2 Accessible routes
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Division 4 except as modified by the exceptions in Section 11B-1003.2....
-
1003.2 Accessible Routes
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Chapter 4 except as modified by the exceptions in 1003.2....
-
Trail Constructed Feature
Examples include puncheon, trail bridges, boardwalks, waterbars, and switchbacks....
-
T402 Ramps and Bridgeplates
[See subsections ...]
-
§ 38.95(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
§ 38.95(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates stowed in the passenger...
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2 percent...
-
1005.1 Accessible Routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Chapter 4. EXCEPTIONS: 1....
-
1005.1 Accessible Routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Chapter 4. EXCEPTIONS: 1....
-
1005.1 Accessible Routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Chapter 4. EXCEPTIONS: 1....
-
11B-1005.1 Accessible routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Division 4....
-
11B-1005.1 Accessible routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Division 4. Exceptions: 1. ...
-
11B-1005.1 Accessible routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Division 4. Exceptions: 1....
-
Accessible Route
The exceptions described under Recreational Boating above also apply to gangways and floating piers....
-
§ 38.125(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
Gangway Slope and Rise Exceptions
This would include a ramp connecting a fixed pier or a float with fixed switchback ramps....