A building or facility or portion of a building or facility designed, constructed, or altered by, on behalf of, or for the use of a public entity subject to title II of the ADA and 28 CFR...
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
Public Building or Facility
-
Honeywell Fire-Lite Alarm BG-12LX Wiring Diagram
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Honeywell Fire-Lite Alarm BG-12 Front Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
Extended Floor or Ground Surface: ADA Standard Section 405.9.1
Section 405.9.1 covers the current ADA Standards for extended floor or ground surface of the ramp run or landing.
-
Surface Hazards: ADA Standard Section 609.5
Section 609.5 covers the current ADA Standards for the surfaces of grab bars and adjacent surfaces.
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
- Activar JL Industries Cosmopolitan Series 2035S21 Stainless Steel Fire Extinguisher Cabinet
-
Shooting Facilities with Firing Positions: ADA Standard Section 243
Section 243 covers scoping requirements in the current ADA Standards for shooting facilities and firing positions.
-
Shooting Facilities with Firing Positions: ADA Standard Section 1010
[See subsections ...]
-
BUILDING OFFICIAL
The officer or other designated authority charged with the administration and enforcement of this code, or a duly authorized representative.
-
NFPA: ADA Standard Section 105.2.5
Section 105.2.5 of the ADA Standards cover references to the National Fire Protection Association (NFPA).
-
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
[See subsections ...]
- Activar JL Industries Ambassador Series 1017F10 Steel Fire Extinguisher Cabinets
-
11B-1010 Shooting facilities with firing positions
[See subsections ...]
-
11B-243 Shooting facilities with firing positions
[See subsections ...]
-
1011.5.2 Cooking Surfaces
Where provided, cooking surfaces shall be 15 inches (380 mm) minimum and 34 inches (865 mm) maximum above the ground....
-
1011.5.2 Cooking Surfaces
Where provided, cooking surfaces shall be 15 inches (380 mm) minimum and 34 inches (865 mm) maximum above the ground....
- Activar JL Industries Academy Series 1027V10 Aluminum Fire Extinguisher Cabinet
-
4.2.2 Cooking Surface Height
The cooking surface shall be at least 15 inches (380 mm) and no more than 34 inches (865 mm) above the floor or ground surface. ...
- Safe-T Systems Fire Guard Portable Fire Extinguisher Stands
-
11B-217.4.3 Building requirement
TTYs in public buildings shall be provided in accordance with Section 11B-217.4.3.1. TTYs in private buildings shall be provided in accordance with Section 11B-217.4.3.2....
-
Qualified Historic Building or Facility
A building or facility that is listed in or eligible for listing in the National Register of Historic Places, or designated as historic under an appropriate State or local law....