In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....
Search Results "Exit Stairway"
-
1009.3 Stairways
-
1009.3.2 Stairway width
Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails....
-
1009.3.1 Exit access stairways
Exit access stairways that connect levels in the same story are not permitted as part of an accessible means of egress....
-
1009.3.2 Stairway width
Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails....
-
1009.3.3 Area of Refuge
Exceptions: Areas of refuge are not required at exit access stairways where two-way communication is provided at the elevator landing in accordance with Section 1009.8....
-
1009.3.3 Area of Refuge
Exceptions: Areas of refuge are not required at exit access stairways where two-way communication is provided at the elevator landing in accordance with Section 1009.8....
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
1009.2, Item 2
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2, Item 3
Exit access stairways complying with Sections 1009.3 and 1019.3 or 1019.4, Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.2, Item 4
Exterior exit stairways complying with Sections 1009.3 and 1027 and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable and serving levels other than...
-
1009.3 Stairways
Exit access stairways that connect levels in the same story are not permitted as part an accessible means of egress....
-
1009.11 Instructions
Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. 2....
-
1013.4, Item 2.1
“EXIT STAIR DOWN”...
-
1013.4, Item 2.3
“EXIT STAIR UP”...
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
-
1023.9 Stairway identification signs
A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of...
-
1009.2 Continuity and components
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....