Exit Sign (6"x3") Part Number 103.01.02 Width = 6" Height = 3" Material = 1/8" thermo formed acrylic...
Search Results "Exit Discharge"
- ADA Sign Products Exit Sign (6" x 3")
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
- Seton ADA Braille Sign - Emergency Exit Only 89424
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
- ADA Sign Depot Exit Sign with Tactile Text and Grade 2 Braille - 5" x 3"
-
ETA Opinion: ADA Signage at Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. §703.2 Raised Characters....
-
1009.3.1 Exit access stairways
Exit access stairways that connect levels in the same story are not permitted as part of an accessible means of egress....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
907.2.9 Group R-2
A fire alarm system shall be installed in Group R-2 occupancies where: Any dwelling unit is located three or more stories above the lowest level of exit discharge; Any...
-
Registered Accessibility Specialist (RAS) Bulletin RAS 2014-04 Signs - Exit Doors
RAS 2014-04 Signs - Exit Doors Effective Date: July 7, 2014 2012 TAS Reference: 216.4.1 In accordance with TAS 216.4.1, doors at exit passageways, exit discharges, and exit...
- Access Board: Exit Signs
-
4.1.3(9)*
Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in...
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
1023.9 Stairway identification signs
The signage shall also state the story of, and the direction to, the exit discharge and the availability of roof access from the interior exit stairway and ramp for the fire department....
-
Egress [4.1.3(9), 4.3.10]
Accessible means of egress are required according to the number of exits provided to meet the building or life safety code....
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
1022.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]