Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADA Standards] 407.3.5 Door Delay....
Search Results "Door Leaf"
Commonly Searched Documents
-
11B-407.3.5 Door delay
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
Width: ADA Standard Section 407.3.6
Section 407.3.6 covers the current ADA Standards for elevator door width.
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Doors in Series and Gates in Series: ADA Standard Section 404.3.4
Section 404.3.4 covers the current ADA Standards for doors in series and gates in series at automatic and power-assisted doors and gates.
-
Revolving Doors, Revolving Gates, and Turnstiles: ADA Standard Section 404.3.7
Section 404.3.7 covers the current ADA Standards for revolving doors, revolving gates, and turnstiles.
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
Doors: ADA Standard Section 604.8.2.2
Section 604.8.2.2 covers the current ADA Standards for ambulatory accessible compartment doors.
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Elevator Doors: ADA Standard Section 409.3
Section 409.3 covers the current ADA Standards for the doors of private residence elevators.
-
Operation: ADA Standard Section 407.3.2
Section 407.3.2 covers the current ADA Standards for elevator door operations.
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
AUTOMATIC DOOR
[DSA-AC] A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
Doors, Doorways, and Gates: ADA Standard Section 206.5
Section 206.5 covers scoping requirements in the most current ADA Standards for accessible routes to doors, doorways, and gates.
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...