Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
Search Results "Clearance Around Base"
-
Toe Clearance: ADA Standard Section 604.8.1.4
-
Platform to Hoistway Clearance: ADA Standard Section 407.4.3
Section 407.4.3 covers the current ADA Standards for the required clearance between the elevator car platform and the hoistway landing.
-
Vertical Clearance: ADA Standard Section 502.5
Section 502.5 covers the current ADA Standards for the vertical clearance required at accessible parking spaces.
-
Clearance in Base (M301.4.1 and M302.4.1)
Clearance in the base of the equipment allows the legs of a portable floor lift to fit under the base of the equipment....
-
Platform to Runway Clearance: ADA Standard Section 410.4
Section 410.4 covers the current ADA Standards for the required clearance between the platform and any runway landing.
-
Clearance: ADA Standard Section 804.2
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
Platform to Hoistway Clearance: ADA Standard Section 409.4.3
Section 409.4.2 covers the ADA Standards for the required clearance between the car platform and the hoistway landing in private residence elevators.
-
11B-809.9.3 Removable base cabinets
Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the...
-
Maneuvering Clearance: ADA Standard Section 305.7
Section 305.7 covers the current ADA Standards for additional maneuvering clearance needed when the clear floor or ground space is located in an alcove.
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
21. Are play areas on military bases subject to the “standards”?
Are play areas on military bases subject to the “standards”? Yes. Most facilities constructed on military bases are covered by the ABA Standards....
-
Platform to Hoistway Clearance: ADA Standard Section 408.4.3
Section 408.4.3 covers the ADA Standards for the required clearance between the car platform and the hoistway landing of limited-use/application elevators.
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
1134A.8, Item 4.3
4.3. Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. The knee and toe space shall be centered...
-
1134A.8, Item 4.3
4.3. Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. The knee and toe space shall be centered on...
-
Vertical Clearance: ADA Standard Section 503.5
Section 503.5 covers the current ADA Standards for the vertical clearance at passenger loading zones.
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed a clearance in the base of 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination...
-
Clearance: ADA Standard Section 607.2
Section 607.2 covers the current ADA Standards for bathtub clearances.
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet....