The clear floor or ground space for telescopes and periscopes shall be at least 36 inches (915 mm) by 48 inches (1220 mm) positioned for forward approach to the telescope or periscope, and...
Search Results "Clear Ground Space"
-
4.6.4 Clear Floor or Ground Space
-
4.6.5 Slope
The slope of the clear floor or ground space required by section 4.6.4 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.6.6 Surface
The surface of the clear floor or ground space required by section 4.6.4 shall be firm and stable. The type of surface should be appropriate to the setting and level of development. ...
-
4.6.7 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
4.7.4 Surface
The surface of the clear floor or ground spaces required by section 4.0 shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
4.7.6 Water Hydrant Clear Floor or Ground Space
Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...
-
4.7.8 Utility and Dump Station Hookup Clear Floor or Ground Space
The clear floor or ground space around utility and dump station hookups shall be at least 30 inches (760 mm) by 60 inches (1525 mm)....
-
4.7.9.2 Clear Floor or Ground Space
Clear floor or ground space 48 inches (1220 mm) by 30 inches (760 mm) oriented for a forward or parallel approach shall be provided for utility sinks required to meet 4.7.9....
-
Outdoor Constructed Features
The proposed rule based the size of the clear ground space at outdoor constructed features on the dimensions for clear floor or ground surfaces in 305.2 of the Architectural Barriers Act...
-
4.8.2 Clear Floor or Ground Space
The clear floor or ground space around outdoor rinsing showers shall be 60 inches (1525 mm) by 60 inches (1525 mm)....
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel to the entrance to the camp shelter....
-
5.1.7 Surface
The surface of the clear ground space shall be firm and stable. ...
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 (2 percent) in any direction....
-
5.1.9 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4. ...
-
1011.1 General
All outdoor constructed features are required to comply with the provisions for clear ground space (1011.2) and operable parts (1011.3)....
-
1011.2 Clear Ground Space
This section requires a clear ground space to be provided at outdoor constructed features and includes specific provisions for the size and location (1011.2.1), surface (1011.2.2), slope...
-
1011.2.1 Size and Location
This section specifies the size and location of the clear ground space at outdoor constructed features....
-
1011.2.3 Slope
This section requires the slope of the clear ground space to not be steeper than 1:48 in any direction....
-
1011.2.4 Openings
This section requires openings in the clear ground space such as drainage grates to not allow passage of a sphere more than 1/2 inch in diameter....
-
1013.2 Clear Ground Space
This section requires a clear ground space 4 feet wide minimum to be provided on all usable sides of tent pads and tent platforms to enable individuals who use wheeled mobility devices to...
-
1015.2 Clear Ground Space
This section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for either a forward or parallel approach to be provided at each distinct viewing location, and...