The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum.
Search Results "Bridging"
Commonly Searched Documents
-
T402.6 Clear Width
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope.
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an...
-
T402.8 Running Slope
The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2.
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is...
-
§ 38.83(c)(6) Attachment
(6) Attachment—
-
§ 38.125(c)(6)(ii) Exception
Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of car devices provided they meet the displacement requirements of paragraph (c)(...
-
§ 38.83(c)(5) Slope
Ramps or bridge plates shall have the least slope practicable....
-
§ 38.95(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...
-
§ 38.83(c)(3) Ramp threshold
The transition from roadway or station platform and the transition from vehicle floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
§ 38.125(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
11B-203.2 Construction sites
Structures and sites directly associated with the actual processes of construction, including but not limited to, scaffolding, bridging, materials hoists, materials storage, and construction...
-
11B-203.2 Construction sites
Structures and sites directly associated with the actual processes of construction, including but not limited to, scaffolding, bridging, materials hoists, materials storage, and construction...
-
§ 38.125(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...
-
§ 38.83(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater then 1/4 inch, shall have a clear width of 30 inches, and shall...
-
§ 38.125(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...
-
Trail Constructed Feature
Examples include puncheon, trail bridges, boardwalks, waterbars, and switchbacks....
-
T503.2 Ramps and Bridgeplates
When ramps or bridgeplates are deployed, the walking surface shall be lighted with 2 foot-candles (22 lux) minimum of illumination.
-
T402.10 Visual Contrast
The perimeter of the walking surface on ramps and bridgeplates shall be marked by a stripe. The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest...
-
§ 38.95(c)(6) Attachment
(6) Attachment—.
-
§ 38.125(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1⁄4 inch....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
§ 38.95(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...
-
T402.5 Surfaces
Ramp and bridgeplate surface material shall comply with T302 and extend across the full width and length of the ramp or bridgeplate.