11B-406.5.6 Grade breaks
-
GRADE BREAK
[DSA-AC] The line where two surface planes with different slopes meet.
-
GRADE BREAK
[DSA-AC] The line where two surface planes with different slopes meet.
-
11B-227.2.1 Altered check-out aisles
Where check-out aisles are altered, at least one of each check-out aisle serving each function shall comply with Section 11B-904.3 until the number of check-out aisles complies with Section...
-
OPEN RISER
[DSA-AC] The space between two adjacent stair treads not closed by a riser.
-
11B-227.2 Check-out aisles
When check-out aisles are open for customer use, the business should ensure that a minimum of one accessible check-out aisle is always available for use by persons with disabilities....
-
Check-Out Aisles and Sales and Service Counters: ADA Standard Section 904
[See subsections ...]
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread....
-
404.1 General
404.1 General. Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by...
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel...
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Openings: ADA Standard Section 302.3
Section 302.3 covers the current ADA Standards for floor and ground surface openings.
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
R302.7.3 Horizontal Openings
R302.7.3 Horizontal Openings. Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 mm (0.5 in) in diameter....
-
11B-216.11 Check-out aisles
check-out aisle identification...
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404. Exceptions: 1. Doors, doorways, and gates designed to be operated only...
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404. Exceptions: 1. Doors, doorways, and gates designed to be operated only by...
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404. Exceptions: Doors, doorways, and gates designed to be operated only by...
-
R408.3 Open Risers
R408.3 Open Risers. Open risers are not permitted....
-
Open Captioning (or Other Technologies) as an Option for Compliance (Section-by-Section Analysis)
For those movie theaters that elect to meet these requirements through the exhibition of movies with open captioning, in whole or in part, the movie theaters may elect to turn on the open...
-
904.3 Check-Out Aisles
904.3 Check-Out Aisles. Check-out aisles shall comply with 904.3....
- Figure 904.3.2 Check-Out Aisle Counters – Drawing from the U.S. Access Board
-
904.3 Check-Out Aisles
Check-out aisles shall comply with 904.3....