404.3 Automatic and Power-Assisted Doors and Gates. Automatic doors and automatic gates shall comply with 404.3....
Search Results "Automatic Door"
-
404.3 Automatic and Power-Assisted Doors and Gates
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
404.3.3 Thresholds
404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with 404.2.5
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Other Requirements in the ADA Standards
Automated Doors Maneuvering clearance is required on the egress side of automated doors unless they are equipped with standby power or they stay open in power-off mode (§404.3.2)...
-
4.13.12* Automatic Doors and Power-Assisted Doors
If an automatic door is used, then it shall comply with ANSI/BHMA A156.10‒1985. Slowly opening, low-powered, automatic doors shall comply with ANSI A156.19‒1984....
-
4.13.12* AUTOMATIC DOORS AND POWER-ASSISTED DOORS
If an automatic door is used, then it shall comply with American National Standard for Power-Operated Doors, ANSI A156.10-1979....
-
Automatic Doors and Power Assisted Doors [4.13.12]
Automatic Doors and Power Assisted Doors [4.13.12] Automated doors are classified by industry standards according to the level of force produced by the door opening....
-
Controls
Clear floor space at controls should be located outside the door swing....
-
Closers
Closers Automated door closing is addressed by the ANSI/BHMA standards....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. [ECTCR UFAS 4.13.5]...
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with 404.2.5.
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....