At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed...
Search Results "Audible Alarm"
-
F232.2.2 Cells with Communication Features
-
4.1.2(13)
(13) If emergency warning systems are provided, then they shall include both audible alarms complying with 4.28.2 and visual alarms complying with 4.28.3....
-
4.1.3(14)
(14) If emergency warning systems are provided, then they shall include both audible alarms and visual alarms complying with 4.28....
-
Visible Alarms
Section 215.3 of the 2010 Standards provides that where employee work areas in newly constructed facilities have audible alarm coverage they are required to have wiring systems that are...
-
4.28 ALARMS
-
4.28 Alarms
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum sound level...
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound level...
-
Scoping [4.1.3(14)]
Scoping [4.1.3(14)] ADAAG requires both audible and visual alarms in facilities that have emergency warning systems whether building-wide systems or self-contained units are provided....
-
Audible Alarms [4.28.2]
Audible Alarms [4.28.2] Sound levels are specified in this section to benefit people who have a hearing impairment....
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
[F] 907.5.2.3.3 Group R-2
visible alarm notification appliances in accordance with NFPA 72....
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems....
-
Public and Common Use Areas: ADA Standard Section 215.2
Section 215.2 covers scoping requirements in the current ADA Standards for fire alarm systems in public and common use areas....
-
Employee Work Areas: ADA Standard Section 215.3
Section 215.3 covers scoping requirements in the current ADA Standards for fire alarm systems in employee work areas....
-
Cells with Communication Features: ADA Standard Section 232.2.2
Section 232.2.2 covers scoping requirements in the current ADA Standards for cells with communication features.
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided....
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. ...
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. [2010 ADA Standards] 215.1 General....