The text of the room identification sign shall be “ADULT CHANGING FACILITY”....
Search Results "Adult Changing Table"
Commonly Searched Documents
-
11B-813.2.12 Signs
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-813.2 Features
Adult changing facilities shall provide features in compliance with Section 11B-813.2....
- MAX-Ability, Inc.
-
11B-813.2.1.1 Size
Adult changing tables shall have a changing surface of 70 inches (1778 mm) minimum length and 30 inches (762 mm) minimum width....
-
11B-813.2.1.4 Capacity
Adult changing tables shall provide a minimum weight capacity of 300 pounds (136 kg)....
- Pressalit Care Adult changing table 3000, electrically height adjustable BIM Detail 2
- Pressalit Care Adult changing table 3000, electrically height adjustable 3D CAD Model
- Pressalit Care Adult changing table 3000, electrically height adjustable BIM Detail 1
- Changing Spaces Campaign
-
11B-249.1.2
Newly constructed commercial places of public amusement shall provide no fewer than one adult changing facility in compliance with Section 11B-813....
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308....
- Pressalit Care Nursing bench 2000, electrically height adjustable
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
11B-813.2.11 Privacy latch
Each door to adult changing facilities shall have a privacy latch....
-
11B-813.2.10 Door swing
provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance required for any fixture, and clearance required for adult...
-
11B-813.2.3 Lavatory
One lavatory in compliance with Section 11B-606.
-
11B-813.2.7 Accessories
Where provided, no fewer than one of each accessory shall comply with Section 11B-603.5.
-
ADULT CHANGING FACILITY
A facility that is for use by persons with disabilities who need assistance with personal hygiene.
-
11B-813.1 Location
Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private room....
-
11B-813.2.4 Waste receptacle
No fewer than one waste receptacle in compliance with Section 11B-603.5.
-
11B-813.2.2 Water closet
No fewer than one water closet in compliance with Section 11B-604.