Adjustable gap protocol
One hundred and fourteen (114) subjects were tested under this protocol and six could not transfer with a gap of any size added between their WMD and the platform in the configuration shown...
-
Side guard protocol
Of the 60 subjects that were able to transfer to a higher level than their own WMD, 98% (59/60), CI[91%,99%] were able to transfer to height of 22” (55.9cm) (Figure 12 and Table 8)....
-
Accessible Round Table Style
Aisles between round tables require at least three feet of space between the tables (measured from the back of one chair to the back of the chair directly behind it)....
-
Bathrooms
Some rooms in larger facilities must have a combination roll-in/ transfer shower....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
The purpose of these sections is to facilitate independent transfer onto and off of diagnostic equipment by patients with disabilities, including those who use mobility devices or aids,...
-
§382.65(c)(1)
1) On-board wheelchairs must include footrests, armrests which are movable or removable, adequate occupant restraint systems, a backrest height that permits assistance to passengers in transferring...
- Guldmann GLS5 Active lifter
- Kompan, Inc. Electronic Playgrounds ICON1012 Space Video
-
3.3.1 Research Data
The Committee also considered findings from University of Pittsburgh study that looked at transfers, specifically at how different conditions affected the abilities of WMD users to transfer...
-
ABA CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
4. ACCESSIBLE ELEMENTS AND SPACES: SCOPE AND TECHNICAL REQUIREMENTS
[See subsections ...]
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
6.1 Deliberative Process
At its first meeting, the Advisory Committee considered this NPRM recommendation of 17” to 19”, which applied to either fixed or adjustable height transfer surfaces....
-
Adjustable height protocol
,96%] of the sample (107/116) could transfer at a height of 22” (50.8cm)....
-
11B-224.2 Guest rooms with mobility features
Provide either a bathtub complying with Section 11B-607 or a transfer type shower complying with Section 11B-608.2.1. 2. ...
-
Sloped Entries
Persons transfer to the aquatic wheelchair and access the water using it, leaving their personal mobility device on the deck....
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
shorter wheelbase than “standard,” the clearance for a lift may use both the clearance in the base and the clearance around the base to position the lift around the stretcher for patient transfers...
-
H. Men's Spa and Fitness Center Locker Room
Clear space sufficient to allow a person using a wheelchair to make a parallel transfer onto the bench will be provided. 2010 Standards §§ 222.1, 305, 803.4, and 903....
-
SEAT HEIGHT MEASUREMENT DETAIL
Measuring to the top of the bolster would account for the maximum transfer height differential from a wheeled mobility device....
-
Side guard protocol
Side guard protocol: From initial setup, two side guards adjusted 6” (15.2 cm) higher than the subject’s WMD seat were attached, and subjects were asked to perform a level height transfer...