racks, log books, and other work assignment or attendance-recording equipment used by people in wheelchairs must be installed at a height no more than 48 in (1220 mm) above the finished floor...
Search Results "Ground Floor Exit"
-
9.6 ATTENDANCE-RECORDING EQUIPMENT
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically to the floor...
-
II-5.1000 General
Civil suits are routinely heard in a courtroom on the second floor of the courthouse. The courthouse has no elevator or other means of access to the second floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
4(5)
(5) Exterior deck, patio, or balcony surfaces are no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed of impervious material such...
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
4.34.6.5(7)
(7) A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall allow forward approach to the sink....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
- Sioux Chief Closet Flange Family Animation Video
-
E2-1. Pedestrian Routes
pedestrian routes leading to or serving the voting area free of objects that protrude from the side more than 4 inches into the route with the bottom of the object more than 27 inches above the floor...
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
1134A.7 Water closets
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Swimming Pools: ADA Standard Section 242.2
Section 242.2 covers scoping requirements in the current ADA Standards for swimming pools.
-
12. What if I have two pools or a pool and a spa? Can I share a lift between pools?
In new construction, each pool or spa must provide accessible entry and exit....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Cross Slope
Where floating piers are grounded out due to low water conditions, slope requirements would not apply....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
6.9 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
11B-204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with Section 11B-307 provided that ground level accessible routes provide vertical clearance in...
- Spectrum Aquatics Glacier Platform Pool Lift
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-V
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-P