Site development and grading shall be designed to provide access to all entrances and exterior ground floor exits, and access to normal paths of travel, and where necessary to provide access...
Search Results "Ground Floor"
-
1127B.1
- Easterseals North Texas
- Coastal Bend Center for Independent Living (CBCIL) - Corpus Christi, TX
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
E.
Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional, sloped-floor...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
1.9.1.2
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
When is accessibility required for a live work conversion project?
Background The building is a 2-story concrete structure with 37,690 sf on the first floor and 22,334 sf on the second floor The building’s freight elevator has been vacated/removed...
- Rebuilding Together Of the Triangle - Raleigh, NC
- Panda S.85 All Aluminum Slim Profile Lift and Slide System
- Guldmann Basic High Sling - Kids