Curb ramp surfaces, including flared sides, must comply with requirements in 4.5 for ground and floor surfaces be "stable, firm, and slip resistant."...
Search Results "Floor Plan"
Commonly Searched Documents
-
Width [4.7.3] and Surface [4.7.4]
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated assemblies (doors, walls, ceilings, and floors...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
Text Telephones (TTY)
Section 217.4.2 of the 2010 Standards requires that a building or facility provide a public TTY on each floor that has four or more public telephones, and in each telephone bank that has...
-
RECOMMENDED CHANGE
medical devices, requires a similar instability test in section 9.4.2.3: ME EQUIPMENT having a mass of 25 kg or more, other than FIXED ME EQUIPMENT that is intended to be used on the floor...
-
Examination Tables
Treatment tables typically have a fixed height of 31 inches measured from the floor to the top of the table. The lower cost products have an open base with an H-brace or shelf....
-
II-6.2100 General
If ADAAG is chosen, however, public entities are not entitled to the elevator exemption (which permits certain buildings under three stories or under 3,000 square feet per floor to be constructed...
-
ACCESSIBLE DWELLING UNITS
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
- Marin Center for Independent Living - San Rafael, CA
- Mansfield Toilet ADA Commercial Package CP-1313
- Cybex Total Access Treadmill
-
Rear Grab Bar
The proposed rule included provisions that make clear floor space requirements at water closets more stringent by not allowing other fixtures, such as lavatories to overlap the space....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
11B-805 Medical care and long-term care facilities
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
Water Play Components
If the surface of the accessible route, clear floor or ground spaces, and turning spaces that connect play components are submerged, the accessible route does not have to comply with the...
-
407.8.2.2 Obstructed Side Reach
more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches (1170 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
4.27.3* Height
Electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
5.5 Food Service Lines
Tray slides shall be mounted no higher than 34 in (865 mm) above the floor (see Fig. 53)....
-
Plumbed Fixtures
Non-fixed units, such as bottled water coolers, are recognized as an option in providing additional access where only one fixed unit is provided on a floor....