It does not provide appropriate access to the building for people with disabilities....
Search Results "Accessible Seating"
-
Common Problems with Routes to Building Entrances
-
1018.10 Dune Crossings
Where the slope of a beach access route at a dune crossing is steeper than 1:20 (5%), handrails complying with 505 and curbs or barriers shall be provided....
-
1018.10 Dune Crossings
Where the slope of a beach access route at a dune crossing is steeper than 1:20 (5%), handrails complying with 505 and curbs or barriers shall be provided....
-
Vertical Clearance [§502.5]
Vertical Clearance [§502.5] A 98” minimum vertical clearance is required for van parking spaces/ access aisles and the vehicle route to these spaces from an entrance and from these...
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]
-
M302.2.1 Adjustability
Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A. A low transfer position...
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within...
-
Overhead Lifts
The technical criteria do not address overhead lifts that are usually mounted on the ceiling and operate on tracks suspended over the diagnostic equipment because the configuration...
-
Clearance in Base (M301.4.1 and M302.4.1)
Clearance in the base of the equipment allows the legs of a portable floor lift to fit under the base of the equipment. The clearance can be an open area between the supporting posts...
- Access Board: Protruding Objects - Post Mounted Objects
- Access Board: Design Solutions for Common Protruding Objects
-
§ 38.113(e) Signage
The International Symbol of Accessibility shall be displayed on the exterior of all doors complying with this section unless all cars and doors are accessible and are not marked by the access...
- Pilot Rock XT and XTH Series End Accessible Picnic Table - Using Steel Tops and Seats
-
11B-503.6 Identification
It shall be permanently posted immediately adjacent to and visible from the passenger loading zone stating “Passenger Loading Zone Only” and including the International Symbol of Accessibility...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve....
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve....
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components: Accessible routes complying with Chapter...
-
2. e. Accessible toilet and dressing rooms
ACCESSIBLE TOILET AND DRESSING ROOMS...
-
Floor and Ground Surfaces: ADA Standard Section 503.4
Section 503.4 covers the current ADA Standards for the floor and ground surfaces at passenger loading zones.
-
§ 35.150(b)(4) Swimming pools, wading pools, and spas
if a public entity chooses to make structural changes to existing swimming pools, wading pools, or spas built before March 15, 2012, for the sole purpose of complying with the program accessibility...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....