Clear floor space is required for a forward approach (902.2), and a surface height of 28 to 34 inches is specified (902.3)....
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
-
902 Dining Surfaces and Work Surfaces
-
APPENDIX A
A key issue addressed in the presentation is that no adjustable height exam tables are currently available that lower to 17 inches above the floor....
-
How to Measure Transfer Surface Height
typical diagonal transfer.24 Figure 11: Corner radii of a medical examination table The depth and width are measured along the centerlines of the seat, and the height from the floor...
-
6.1 Deliberative Process
Box 6.1 M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top...
-
704.11 Parapets
The building has an area of not more than 1,000 square feet (93 m2) on any floor. 3....
-
Minimum Clear Opening
These commenters supported Option Two's approach, which provided for clear width to be determined by the clear floor space available for maneuvering on both sides of the door, with the minimum...
-
Alterations and Additions
Additions, which include an expansion, extension or increase of the gross floor area of a building or facility, are considered an alteration to a facility but the area that is added must...
-
CCDA Accessibility Checklist for Building Inspectors, 2015 Edition
During construction inspection finish product thicknesses such as flooring materials or wall coverings must be considered when reviewing critical accessibility features, including but not...
-
Section 36.406(g) Medical Care Facilities (Section-by-Section Analysis)
comment on the issue, asking whether it should require medical care facilities, such as hospitals, to disperse their accessible sleeping rooms, and if so, by what method (by specialty area, floor...
-
Checklist for Inclusive Emergency Safety Briefings for Attendees
take any stairwell and exit at the ground floor, Incorporating slides and / or pictures in the briefing can increase attention and understanding for those...
-
Test Procedures
It has been correlated to the work measurement done in ASTM F1951, Accessibility of Surface Systems, for a wide array of surfacing and floor coverings....
-
DEFENDANTS’ RAISED PORCHES
The entrances with doors that flank the raised porches are not similarly covered by a roof and do not have furniture, marketing items, and a wooden floor. ...
-
11B-604.5.2 Rear wall
There are wall-mounted bedpan washing devices that could be used instead, taking care not to obstruct either the side or the rear grab bars, or the required clear floor space....
-
Section 35.151(h) Medical care facilities (Section-by-Section Analysis)
comment on the issue, asking whether it should require medical care facilities, such as hospitals, to disperse their accessible sleeping rooms, and if so, by what method (by specialty area, floor...
-
11B-1003.2.1 Boat slips
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
II-1.3000 Relationship to title III
The building's first floor, however, is leased to a restaurant, a newsstand, and a travel agency....
-
11B-604.5.2 Rear wall
There are wall-mounted bedpan washing devices that could be used instead, taking care not to obstruct either the side or the rear grab bars, or the required clear floor space....
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
-
11B-104.1.1 Construction and manufacturing tolerances
Where the requirement states a specified range, such as in Section 11B-609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate...
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....